{"id":34661,"date":"2023-03-09T12:12:11","date_gmt":"2023-03-09T11:12:11","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=pubblicazione&#038;p=34661"},"modified":"2023-06-30T12:49:48","modified_gmt":"2023-06-30T11:49:48","slug":"chapitre-7-les-architectures-de-la-cei-62061","status":"publish","type":"pubblicazione","link":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/","title":{"rendered":"Chapitre 7 &#8211; Les architectures de la IEC 62061"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/Capture6-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"97\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/Capture6-300x97.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 606px)\"\r\n                                width=\"606\"\r\n                                height=\"195\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/Capture6.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 606px)\"\r\n                                width=\"606\"\r\n                                height=\"195\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/Capture6.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/Capture6.png.webp\"\r\n                                                        title=\"Capture6\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p><strong>Le chapitre 7<\/strong> traite <strong>des quatre architectures de la IEC 62061<\/strong>. La IEC 62061 reste li\u00e9e \u00e0 l&rsquo;approche de la Route 1H de la IEC 61508.<\/p>\n<p>En mode \u00ab\u00a0faible demande\u00a0\u00bb, les composants sont class\u00e9s comme \u00e9tant de type A ou de type B et il existe deux tableaux diff\u00e9rents \u00e0 utiliser pour d\u00e9terminer le SIL maximal qu&rsquo;un sous-syst\u00e8me de s\u00e9curit\u00e9 peut atteindre. Dans la IEC 62061, un seul tableau est d\u00e9fini pour tous les types de composants et son contenu est similaire \u00e0 celui utilis\u00e9 pour les composants de type B.<\/p>\n<p>Dans le contexte de l&rsquo;int\u00e9grit\u00e9 de la s\u00e9curit\u00e9 du mat\u00e9riel, le niveau le plus \u00e9lev\u00e9 auquel peut pr\u00e9tendre un syst\u00e8me de commande de s\u00e9curit\u00e9 ou un SCS est limit\u00e9 par les tol\u00e9rances de d\u00e9faillance du mat\u00e9riel (HFT) et les fractions de d\u00e9faillance s\u00fbres (SFF) du sous-syst\u00e8me qui ex\u00e9cute la fonction de s\u00e9curit\u00e9 : la r\u00e9f\u00e9rence \u00e0 utiliser est le tableau 6 pr\u00e9sent\u00e9 ci-apr\u00e8s.<\/p>\n<p>Voici quelques extraits du chapitre.<\/p>\n<p><strong>7.1.1 Contraintes architecturales<\/strong><\/p>\n<p>La IEC 62061 reste li\u00e9e \u00e0 l&rsquo;approche de la Route 1H de la IEC 61508, d\u00e9crite au \u00a7 3.4.8.<\/p>\n<p>En mode \u00ab\u00a0faible demande\u00a0\u00bb, les composants sont class\u00e9s comme \u00e9tant de type A ou de type B, et il existe deux tableaux diff\u00e9rents \u00e0 utiliser pour d\u00e9cider du SIL maximal qu&rsquo;un sous-syst\u00e8me de s\u00e9curit\u00e9 peut atteindre. Dans la IEC 62061, un seul tableau est d\u00e9fini pour tous les types de composants, et son contenu est similaire \u00e0 celui utilis\u00e9 pour les composants de type B.<\/p>\n<p>Dans le contexte de l&rsquo;int\u00e9grit\u00e9 de la s\u00e9curit\u00e9 du mat\u00e9riel, le niveau le plus \u00e9lev\u00e9 auquel peut pr\u00e9tendre un syst\u00e8me de contr\u00f4le ou SCS li\u00e9 \u00e0 la s\u00e9curit\u00e9 est limit\u00e9 par les tol\u00e9rances de d\u00e9faillance du mat\u00e9riel (HFT) et les fractions de d\u00e9faillance s\u00fbres (SFF) du sous-syst\u00e8me qui ex\u00e9cute la fonction de s\u00e9curit\u00e9 : la r\u00e9f\u00e9rence \u00e0 utiliser est le tableau 7.1, identique au tableau 6 de la IEC 62061.<\/p>\n<p><strong>7.1.2.1 Diff\u00e9rences avec la norme ISO 13849-1<\/strong><\/p>\n<p>Les diff\u00e9rences entre les deux normes sont les suivantes :<\/p>\n<ul>\n<li>Comme expliqu\u00e9 au \u00a7 3.6.2, dans la IEC 62061, le risque de d\u00e9faillances de cause commune est \u00e9valu\u00e9 \u00e0 l&rsquo;aide d&rsquo;un tableau similaire \u00e0 celui de l&rsquo;ISO 13849-1, mais<strong> il n&rsquo;y a pas de valeur minimale pour la notation.<\/strong><\/li>\n<li>Dans la cat\u00e9gorie 2, l&rsquo;ISO 13849-1 exige que la valeur MTTFD du canal d&rsquo;essai (TE) ne soit pas inf\u00e9rieure \u00e0 la moiti\u00e9 de la valeur MTTFD du canal fonctionnel. L&rsquo;\u00e9quivalent de la cat\u00e9gorie 2 dans la IEC 62061 est l&rsquo;architecture du sous-syst\u00e8me de base C. Dans ce cas, cependant, il n&rsquo;y a pas de niveau de fiabilit\u00e9 minimal de la fonction de traitement des d\u00e9faillances (\u03bbD-FH). Si la valeur n&rsquo;est pas conforme au tableau H.3 de la norme, la formule simplifi\u00e9e ne peut pas \u00eatre utilis\u00e9e pour le calcul de la PFHD du sous-syst\u00e8me. <strong>La formule g\u00e9n\u00e9rale pour l&rsquo;architecture du sous-syst\u00e8me de base C doit \u00eatre utilis\u00e9e.<\/strong><\/li>\n<li>Dans la norme ISO 13849-1, la MTTFD des sous-syst\u00e8mes est limit\u00e9e \u00e0 100 ans, sauf pour la cat\u00e9gorie 4 ; dans la IEC 62061, <strong>il n&rsquo;y a pas de limitation de la PFHD, m\u00eame lorsque la contrainte architecturale est appliqu\u00e9e.<\/strong><\/li>\n<li>La IEC 62061 utilise l&rsquo;acronyme PFH, mais <strong>il s&rsquo;agit exactement du m\u00eame param\u00e8tre que le PFHD<\/strong> utilis\u00e9 dans l&rsquo;ISO 13849-1 (\u00a7 4.5.1). La raison en est l&rsquo;alignement sur la s\u00e9rie IEC 61508.<\/li>\n<\/ul>\n<p>[&#8230;]<\/p>\n<p><strong>7.2.4.2 Architecture du sous-syst\u00e8me de base C avec traitement des d\u00e9fauts par le SCS<\/strong><\/p>\n<p>Il s&rsquo;agit de la situation la plus simple, puisque <strong>les fonctions de diagnostic et de r\u00e9action aux d\u00e9faillances (\u00e9quivalentes \u00e0 TE et OTE dans la norme ISO 13849-1) font d\u00e9j\u00e0 partie de la fonction de s\u00e9curit\u00e9<\/strong>, comme le montre la figure 7.10.<\/p>\n<p><strong>La fonction de traitement des d\u00e9faillances <\/strong>est enti\u00e8rement assur\u00e9e par un sous-syst\u00e8me distinct du SCS, qui participe \u00e9galement \u00e0 l&rsquo;ex\u00e9cution de la fonction de s\u00e9curit\u00e9, contribuant ainsi \u00e0 sa PFHD.<\/p>\n<p>En d&rsquo;autres termes, dans ce cas, nous pouvons ignorer la fiabilit\u00e9 de la voie de surveillance puisqu&rsquo;elle est d\u00e9j\u00e0 prise en compte dans le calcul de la fiabilit\u00e9 de la voie fonctionnelle.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>Le chapitre 7 traite des quatre architectures de la IEC 62061. La IEC 62061 reste li\u00e9e \u00e0 l&rsquo;approche de la Route 1H de la IEC 61508.<\/p>\n","protected":false},"author":2,"featured_media":35568,"parent":34571,"menu_order":7,"template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-34661","pubblicazione","type-pubblicazione","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"Le chapitre 7 traite des quatre architectures de la IEC 62061. La IEC 62061 reste li\u00e9e \u00e0 l&#039;approche de la Route 1H de la IEC 61508.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-30T11:49:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"564\" \/>\n\t<meta property=\"og:image:height\" content=\"380\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/\",\"name\":\"Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg\",\"datePublished\":\"2023-03-09T11:12:11+00:00\",\"dateModified\":\"2023-06-30T11:49:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg\",\"width\":564,\"height\":380},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Publications\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"S\u00e9curit\u00e9 fonctionnelle des machines\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Chapitre 7 &#8211; Les architectures de la IEC 62061\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/","og_locale":"fr_FR","og_type":"article","og_title":"Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering","og_description":"Le chapitre 7 traite des quatre architectures de la IEC 62061. La IEC 62061 reste li\u00e9e \u00e0 l'approche de la Route 1H de la IEC 61508.","og_url":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/","og_site_name":"Gt-Engineering","article_modified_time":"2023-06-30T11:49:48+00:00","og_image":[{"width":564,"height":380,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/","url":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/","name":"Chapitre 7 - Les architectures de la IEC 62061 - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg","datePublished":"2023-03-09T11:12:11+00:00","dateModified":"2023-06-30T11:49:48+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/03\/IEC-62061-Architecture-A.jpg","width":564,"height":380},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/chapitre-7-les-architectures-de-la-cei-62061\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.gt-engineering.it\/fr\/"},{"@type":"ListItem","position":2,"name":"Publications","item":"https:\/\/www.gt-engineering.it\/fr\/publications\/"},{"@type":"ListItem","position":3,"name":"S\u00e9curit\u00e9 fonctionnelle des machines","item":"https:\/\/www.gt-engineering.it\/fr\/publications\/securite-fonctionnelle-des-machines\/"},{"@type":"ListItem","position":4,"name":"Chapitre 7 &#8211; Les architectures de la IEC 62061"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/fr\/#website","url":"https:\/\/www.gt-engineering.it\/fr\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/pubblicazione\/34661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/pubblicazione"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/types\/pubblicazione"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":4,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/pubblicazione\/34661\/revisions"}],"predecessor-version":[{"id":37276,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/pubblicazione\/34661\/revisions\/37276"}],"up":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/pubblicazione\/34571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media\/35568"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media?parent=34661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}