{"id":49503,"date":"2025-08-18T11:36:23","date_gmt":"2025-08-18T10:36:23","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=normativa_tecnica&#038;p=49503"},"modified":"2026-02-26T10:19:56","modified_gmt":"2026-02-26T09:19:56","slug":"ul-508a-mise-a-jour-de-juillet-2022","status":"publish","type":"normativa_tecnica","link":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/","title":{"rendered":"UL 508A \u2013 Mise \u00e0 jour de juillet 2022"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n            <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p><strong><u><span dir=\"auto\">Une nouvelle mise \u00e0 jour de la norme a \u00e9t\u00e9 officiellement publi\u00e9e le juillet 2022.<\/span><\/u><\/strong><span dir=\"auto\">\u00a0 Nous vous donnons ci-apr\u00e8s un aper\u00e7u des principaux changements.<\/span><\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    AMPERE DE PLEINE CHARGE vs. COURANT DE PLEINE CHARGE    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Dans le pass\u00e9, en tant que GT Engineering, nous avons toujours discut\u00e9 du fait que les termes\u00a0<strong>FLA et FLC<\/strong>\u00a0n\u2019\u00e9taient pas utilis\u00e9s avec pr\u00e9cision dans le texte de la norme UL 508A. C\u2019est pourquoi, en 2021, nous avons soumis une demande visant \u00e0 aligner l\u2019utilisation de ces deux termes sur le NEC. Voici quelques r\u00e9flexions sur les changements.<\/p>\n<p>\u00ab\u00a0La norme UL 508A, dans la clause 52.1 (qui renvoie \u00e0 la clause 49.1), exige que la plaque de panneau indique l\u2019\u00a0\u00bb<strong>intensit\u00e9 nominale \u00e0 pleine charge<\/strong>\u00ab\u00a0. La norme NFPA 79 parle de \u00ab\u00a0courant de pleine charge\u00a0\u00bb (article 16.4). Le NEC (NFPA 70) exige, dans l\u2019article 670.3(A)(1), que la plaque signal\u00e9tique comporte une liste d\u2019informations, dont le \u00ab\u00a0courant de pleine charge\u00a0\u00bb de l\u2019appareillage de connexion.<\/p>\n<p>L\u2019utilisation de \u00ab\u00a0Full-load ampere rating\u00a0\u00bb dans la norme UL 508A devrait \u00eatre remplac\u00e9e par\u00a0<strong>\u00ab\u00a0Full-load current\u00a0\u00bb<\/strong>, o\u00f9 la signification est la m\u00eame que dans la norme NFPA 79 ou le NEC. Plus pr\u00e9cis\u00e9ment, la section 29.6.1 de la norme UL 508A nomme les courants du tableau 50.1 \u00ab\u00a0Full-load ampere rating\u00a0\u00bb. Le tableau est \u00e9quivalent au tableau du NEC 430.250 et le nom utilis\u00e9 est \u00ab\u00a0Full-load current\u00a0\u00bb (courant de pleine charge). Le titre du tableau 50.1 est \u00ab\u00a0Full-load motor-running currents in amperes corresponding to various a-c horsepower ratings\u00a0\u00bb, alors que le tableau \u00e9quivalent dans NEC est le tableau 430.250 \u00ab\u00a0Full-Load Current, Three-Phase Alternating-Current Motors\u00a0\u00bb. Nous avons propos\u00e9 de modifier le titre du tableau 50.1 en \u00ab\u00a0Full-Load currents in amperes corresponding to various a-c horsepower ratings\u00a0\u00bb.<\/p>\n<p>Cette proposition a \u00e9t\u00e9 accueillie favorablement et sera mise en \u0153uvre dans la nouvelle \u00e9dition de la norme. L\u2019aspect le plus important est probablement le fait que sur la plaque signal\u00e9tique, se r\u00e9f\u00e9rant \u00e0 l\u2019ensemble du panneau de commande, il ne sera plus indiqu\u00e9 \u00ab\u00a0Total FLA\u00a0\u00bb mais le terme plus correct \u00ab\u00a0Full-load current (FLC)\u00a0\u00bb.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    TEMP\u00c9RATURE DE TERMINAISON    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <section id=\"\" class=\"bow-gte-testo-media u-spacer-2xs\" data-name=\"Contenuto testuale con immagine\">\n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n<div class=\"relative w-full\">\n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n<p>Un autre changement dans la version 2022 de la norme UL 508A est li\u00e9 \u00e0 la mani\u00e8re de<strong>\u00a0choisir entre les colonnes 60\u00b0C et 75\u00b0C dans le tableau 28.1.<\/strong><br \/>\nL\u2019un des aspects importants de l<strong>a r\u00e9duction du risque d\u2019incendie est que le courant admissible du c\u00e2ble doit \u00e9galement \u00eatre d\u00e9termin\u00e9 en fonction de la temp\u00e9rature maximale que les bornes d\u2019un disjoncteur<\/strong>, par exemple, peuvent atteindre. Cela est clairement indiqu\u00e9 dans le NEC \u00e0 l\u2019article 110.14(C).<\/p>\n<blockquote><p>[NEC : 2020] 110.14 (C) Temperature Limitations.<br \/>\nLa temp\u00e9rature nominale associ\u00e9e \u00e0 l\u2019ampacit\u00e9 d\u2019un conducteur doit \u00eatre choisie et coordonn\u00e9e de mani\u00e8re \u00e0 ne pas d\u00e9passer la temp\u00e9rature nominale la plus basse de toute terminaison, de tout conducteur ou de tout dispositif raccord\u00e9. [\u2026]<\/p><\/blockquote>\n<p>Le probl\u00e8me est que tous les composants ne pr\u00e9cisent pas quelle est la temp\u00e9rature maximale de leurs terminaisons. Normalement, elle peut \u00eatre de 60\u00b0C ou de 75\u00b0C. Une clarification est donc n\u00e9cessaire pour d\u00e9terminer le courant admissible des conducteurs internes, car la mani\u00e8re d\u2019utiliser le tableau 28.1 n\u2019est pas claire en ce qui concerne les diff\u00e9rents courants admissibles en fonction de la temp\u00e9rature d\u2019isolation du conducteur (<strong>colonne 60\u00b0C contre colonne 75\u00b0C)<\/strong>. Cette r\u00e9vision s\u2019aligne \u00e9galement sur les exigences de la section 110. 14(C)(1) du NEC. Bien que cette section traite des terminaisons de c\u00e2blage sur le terrain,\u00a0<strong>elle \u00e9tablit les exigences minimales pour les temp\u00e9ratures nominales des conducteurs \u00e0 l\u2019int\u00e9rieur d\u2019un panneau de contr\u00f4le industriel<\/strong>\u00a0utilis\u00e9 dans des circuits de 100 amp\u00e8res ou moins et des circuits de plus de 100 amp\u00e8res.<\/p>\n<blockquote><p><strong>[UL 508A : 2022]<\/strong>\u00a029.6 Dimensionnement<br \/>\n[\u2026]<br \/>\nLa temp\u00e9rature nominale du fil indiqu\u00e9e sur le composant ou dans les instructions doit \u00eatre utilis\u00e9e pour s\u00e9lectionner la ou les colonnes appropri\u00e9es du tableau 28.1 comme suit :<br \/>\n1) [\u2026]<br \/>\n4) Si la temp\u00e9rature nominale des fils n\u2019est pas indiqu\u00e9e sur le composant ou dans les instructions, le calibre du conducteur doit \u00eatre d\u00e9termin\u00e9 en utilisant les intensit\u00e9s de la colonne 60\u00b0C du tableau 28.1 lorsque le composant a une intensit\u00e9 nominale de 100 amp\u00e8res ou moins, et de la colonne 75\u00b0C du tableau 28.1 lorsque le composant a une intensit\u00e9 nominale de plus de 100 amp\u00e8res.<\/p><\/blockquote>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"\" class=\"bow-gte-testo-media u-spacer-2xs\" data-name=\"Contenuto testuale con immagine\">\n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n<div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n<div class=\"m-headings\"><\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    TEMP\u00c9RATURE AMBIANTE    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Il est enfin possible de certifier les panneaux de contr\u00f4le industriels install\u00e9s \u00e0 des temp\u00e9ratures ambiantes sup\u00e9rieures \u00e0 40\u00b0C. Cela \u00e9tait d\u00e9j\u00e0 autoris\u00e9 au Canada et l\u2019est d\u00e9sormais \u00e9galement aux \u00c9tats-Unis. La nouvelle formulation se trouve dans la<strong>\u00a0section 1.1<\/strong>\u00a0de la norme UL 508A 2022.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    DISJONCTEUR DE CLASSE A OBLIGATOIRE SUR LES PRISES    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Avec la mise \u00e0 jour 2022 de l\u2019UL 508A, la norme est d\u00e9sormais enti\u00e8rement align\u00e9e sur la NFPA 79 (et la IEC 60204-1) en ce qui concerne l\u2019exigence d\u2019un disjoncteur de fuite \u00e0 la terre de classe A sur toutes les prises de courant \u00e0 usage g\u00e9n\u00e9ral. La nouvelle formulation se trouve dans la\u00a0<strong>section 66.4.4.<\/strong><\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    ACC\u00c8S AU TABLEAU    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La mise \u00e0 jour de 2022 a align\u00e9 les exigences relatives \u00e0 l\u2019acc\u00e8s \u00e0 l\u2019enceinte sur la norme NFPA 79. En r\u00e8gle g\u00e9n\u00e9rale, le verrouillage des portes n\u2019est plus requis. Il n\u2019est plus n\u00e9cessaire de verrouiller toutes les portes lorsqu\u2019il y a du courant \u00e0 l\u2019int\u00e9rieur de l\u2019enceinte. Il n\u2019est plus n\u00e9cessaire d\u2019ouvrir le sectionneur du tableau principal pour ouvrir les portes. Nous disposons \u00e0 pr\u00e9sent d\u2019une approche internationale similaire en ce qui concerne le risque de contact direct \u00e0 l\u2019int\u00e9rieur d\u2019un panneau d\u2019automatisation, \u00e9tant donn\u00e9 que les normes IEC 60204-1, NFPA 79, UL 508A, C22.2 n\u00b0 301 et C22.2 n\u00b0 286 ont \u00e9t\u00e9 quelque peu normalis\u00e9es \u00e0 cet \u00e9gard.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    CONSID\u00c9RATIONS    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La norme\u00a0<strong>UL 508A<\/strong>\u00a0ne concerne que les tableaux d\u2019automatisation (panneaux de contr\u00f4le industriels), dans lesquels se trouvent par exemple des automates programmables, des contacteurs, des variateurs ; tandis que pour les tableaux de distribution (tableaux de distribution), dans lesquels se trouvent g\u00e9n\u00e9ralement des syst\u00e8mes de barres omnibus, il convient de se r\u00e9f\u00e9rer \u00e0 la norme UL 891. Il convient de noter que la norme UL 508A contient d\u00e9sormais des exigences relatives au dimensionnement des tableaux de distribution \u00e0 l\u2019int\u00e9rieur desquels se trouvent des syst\u00e8mes de barres omnibus.<\/p>\n<p>Pour \u00eatre utilis\u00e9 dans un \u00ab\u00a0panneau de contr\u00f4le industriel\u00a0\u00bb, tout composant doit \u00eatre certifi\u00e9 (\u00ab\u00a0r\u00e9pertori\u00e9\u00a0\u00bb ou \u00ab\u00a0reconnu\u00a0\u00bb).<\/p>\n<p>Toutefois, cela ne suffit pas pour que le tableau soit conforme \u00e0 la norme UL 508A. Le dimensionnement des d\u00e9marreurs de moteur et de l\u2019interrupteur principal ob\u00e9it \u00e0 des r\u00e8gles diff\u00e9rentes de celles de la norme EN 60204-1. Les principaux probl\u00e8mes que l\u2019on peut rencontrer en ce qui concerne l\u2019homologation des panneaux de contr\u00f4le aux \u00c9tats-Unis sont les suivants :<\/p>\n<p>des interrupteurs certifi\u00e9s mais utilis\u00e9s de mani\u00e8re incorrecte. Outre le dimensionnement, il faut faire tr\u00e8s attention \u00e0 l\u2019utilisation des interrupteurs qui, selon leur certification (UL1077, UL489, etc.), doivent avoir des applications tr\u00e8s sp\u00e9cifiques \u00e0 l\u2019int\u00e9rieur du tableau.<br \/>\nNon-conformit\u00e9 des distances \u00e9lectriques entre les c\u00e2bles, les appareils, etc.<br \/>\nAbsence de plaque signal\u00e9tique du tableau ou informations incompl\u00e8tes sur les caract\u00e9ristiques du tableau.<br \/>\nTransformateurs non certifi\u00e9s selon la norme technique correspondante ou certifi\u00e9s uniquement au niveau de l\u2019isolation des conducteurs.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>Dans le pass\u00e9, en tant que GT Engineering, nous avons toujours discut\u00e9 du fait que les termes\u00a0FLA et FLC\u00a0n\u2019\u00e9taient pas utilis\u00e9s avec pr\u00e9cision dans le texte de la norme UL 508A.<\/p>\n","protected":false},"author":2,"featured_media":51364,"parent":39459,"menu_order":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"normative-tecniche":[167],"class_list":["post-49503","normativa_tecnica","type-normativa_tecnica","status-publish","has-post-thumbnail","hentry","tipologia_normativa-normes-americaine"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"Dans le pass\u00e9, en tant que GT Engineering, nous avons toujours discut\u00e9 du fait que les termes\u00a0FLA et FLC\u00a0n\u2019\u00e9taient pas utilis\u00e9s avec pr\u00e9cision dans le texte de la norme UL 508A.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-26T09:19:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png\" \/>\n\t<meta property=\"og:image:width\" content=\"430\" \/>\n\t<meta property=\"og:image:height\" content=\"387\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/\",\"name\":\"UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png\",\"datePublished\":\"2025-08-18T10:36:23+00:00\",\"dateModified\":\"2026-02-26T09:19:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png\",\"width\":430,\"height\":387},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Normes techniques\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/normative-tecniche\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Normes USA\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"UL 508A: Panneaux de contr\u00f4le industriels\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"UL 508A \u2013 Mise \u00e0 jour de juillet 2022\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/","og_locale":"fr_FR","og_type":"article","og_title":"UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering","og_description":"Dans le pass\u00e9, en tant que GT Engineering, nous avons toujours discut\u00e9 du fait que les termes\u00a0FLA et FLC\u00a0n\u2019\u00e9taient pas utilis\u00e9s avec pr\u00e9cision dans le texte de la norme UL 508A.","og_url":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/","og_site_name":"Gt-Engineering","article_modified_time":"2026-02-26T09:19:56+00:00","og_image":[{"width":430,"height":387,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/","url":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/","name":"UL 508A \u2013 Mise \u00e0 jour de juillet 2022 - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png","datePublished":"2025-08-18T10:36:23+00:00","dateModified":"2026-02-26T09:19:56+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/08\/Immagine-2026-02-26-101750.png","width":430,"height":387},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/ul-508a-mise-a-jour-de-juillet-2022\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.gt-engineering.it\/fr\/"},{"@type":"ListItem","position":2,"name":"Normes techniques","item":"https:\/\/www.gt-engineering.it\/fr\/normative-tecniche\/"},{"@type":"ListItem","position":3,"name":"Normes USA","item":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/"},{"@type":"ListItem","position":4,"name":"UL 508A: Panneaux de contr\u00f4le industriels","item":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-americaine\/ul-508a\/"},{"@type":"ListItem","position":5,"name":"UL 508A \u2013 Mise \u00e0 jour de juillet 2022"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/fr\/#website","url":"https:\/\/www.gt-engineering.it\/fr\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/49503","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/types\/normativa_tecnica"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":4,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/49503\/revisions"}],"predecessor-version":[{"id":51368,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/49503\/revisions\/51368"}],"up":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/39459"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media\/51364"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media?parent=49503"}],"wp:term":[{"taxonomy":"tipologia_normativa","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normative-tecniche?post=49503"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}