{"id":36597,"date":"2023-01-04T17:58:27","date_gmt":"2023-01-04T16:58:27","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=normativa_tecnica&#038;p=36597"},"modified":"2025-07-07T08:43:35","modified_gmt":"2025-07-07T07:43:35","slug":"6-protection-contre-les-chocs-electriques","status":"publish","type":"normativa_tecnica","link":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/","title":{"rendered":"6 &#8211; Protection contre les chocs \u00e9lectriques"},"content":{"rendered":"\n\n    \n        \n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start flex-col\">\n\n    \n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p><strong>Le chapitre 6<\/strong> est une norme d\u00e9crivant <strong>les mesures de protection contre les chocs \u00e9lectiques<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<blockquote><p><em>Les pi\u00e8ces sous tension doivent \u00eatre plac\u00e9es \u00e0 l&rsquo;int\u00e9rieur d&rsquo;enveloppes offrant une protection contre le contact avec les pi\u00e8ces sous tension d&rsquo;au moins <a href=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/protection-from-direct-contacts-ipxxb-or-ip2x\/\">IP2X ou IPXXB<\/a>.<\/em><\/p><\/blockquote>\n<\/div>\n            <\/div>\n        \n                    <div\n                class=\"h-auto mt-6 md:mt-4 lg:mt-8 xl:mt-9 overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"133\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-300x133.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"340\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-768x340.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"454\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-1024x454.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1.png.webp\"\r\n                                                        title=\"agg sito 2\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"133\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-300x133.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"340\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-768x340.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"454\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1-1024x454.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/agg-sito-2-1.png.webp\"\r\n                                                        title=\"agg sito 2\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start flex-col\">\n\n    \n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La norme \u00e9nonce les conditions suivantes pour l&rsquo;ouverture de l&rsquo;enveloppe, en pr\u00e9cisant quand elles doivent \u00eatre adopt\u00e9es :<br \/>\n<strong>&#8211; Bo\u00eetier pouvant \u00eatre ouvert \u00e0 l&rsquo;aide d&rsquo;une cl\u00e9 ou d&rsquo;un outil<\/strong> ; dans ce cas, le sectionneur se trouve sur le c\u00f4t\u00e9 de l&rsquo;armoire, le tableau de distribution doit avoir un niveau de protection IP XXB ou sup\u00e9rieur \u00e0 l&rsquo;int\u00e9rieur de celle-ci dans les zones accessibles \u00e0 l&rsquo;op\u00e9rateur.<br \/>\n<strong>&#8211; Bo\u00eetier pouvant \u00eatre ouvert \u00e0 la suite d&rsquo;une d\u00e9connexion de pi\u00e8ces sous tension ;<\/strong> Le sectionneur est pr\u00e9sent \u00e0 l&rsquo;avant, sur la porte de l&rsquo;armoire. Comme il ne peut \u00eatre manipul\u00e9 qu&rsquo;en l&rsquo;absence de tension, il n&rsquo;y a pas d&rsquo;exigences en mati\u00e8re de niveaux de s\u00e9curit\u00e9 minimaux ; toutefois, s&rsquo;il existe un syst\u00e8me de d\u00e9rivation qui permet d&rsquo;ouvrir la porte lorsque la tension est pr\u00e9sente, les exigences du point pr\u00e9c\u00e9dent doivent \u00eatre appliqu\u00e9es.<br \/>\n<strong>&#8211; Enveloppe pouvant \u00eatre ouverte sans l&rsquo;aide d&rsquo;une cl\u00e9 ou d&rsquo;un outil et sans d\u00e9connexion des parties sous tension.<\/strong> TOUS les composants de l&rsquo;enveloppe doivent avoir un niveau de protection IP XXB.<\/p>\n<p>Le point<strong> 6.3<\/strong> \u00e9num\u00e8re les protections de s\u00e9curit\u00e9 destin\u00e9es \u00e0 emp\u00eacher l&rsquo;apparition de conditions dangereuses en cas de d\u00e9faillance de l&rsquo;isolation entre les parties actives et les masses. <strong>Des mesures doivent \u00eatre pr\u00e9vues pour chaque circuit ou partie de l&rsquo;\u00e9quipement afin d&#8217;emp\u00eacher l&rsquo;apparition d&rsquo;une tension de contact, ou une d\u00e9connexion automatique de l&rsquo;alimentation<\/strong> doit \u00eatre mise en \u0153uvre avant que la dur\u00e9e du contact avec une partie sous tension ne devienne une condition dangereuse.<\/p>\n<p><strong>Les mesures visant \u00e0 pr\u00e9venir l&rsquo;apparition d&rsquo;une tension de contact<\/strong> sont les suivantes :<br \/>\n&#8211; Utilisation de mat\u00e9riel de classe II ou d&rsquo;une isolation \u00e9quivalente ;<br \/>\n&#8211; la s\u00e9paration \u00e9lectrique.<\/p>\n<p>La <strong>coupure automatique de l&rsquo;alimentation \u00e9lectrique<\/strong> de tout circuit affect\u00e9 par un d\u00e9faut d&rsquo;isolement est destin\u00e9e \u00e0 pr\u00e9venir une situation dangereuse r\u00e9sultant d&rsquo;une tension de contact. Cette mesure consiste \u00e0 interrompre un ou plusieurs conducteurs de ligne par l&rsquo;intervention automatique d&rsquo;un dispositif de protection en cas de d\u00e9faut. L&rsquo;interruption doit se produire dans un temps court afin de limiter la dur\u00e9e de la tension de contact \u00e0 une p\u00e9riode comprise dans les limites sp\u00e9cifi\u00e9es \u00e0 l&rsquo;annexe A de la norme pour les syst\u00e8mes TN et TT.<\/p>\n<p>Si vous \u00eates int\u00e9ress\u00e9 par une \u00e9tude approfondie, vous pouvez la trouver sur le <span style=\"color: #008080;\"><a style=\"color: #008080;\" href=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/panneaux-de-controle-industriels-et-porte-interlock\/\"><strong>lien<\/strong><\/a><\/span> suivant<\/p>\n<\/div>\n            <\/div>\n        \n        \n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/4\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/INTERRUZIONE-6.3.jpg-2-150x150.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"169\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/INTERRUZIONE-6.3.jpg-2-300x169.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"431\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/INTERRUZIONE-6.3.jpg-2-768x431.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"575\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/INTERRUZIONE-6.3.jpg-2-1024x575.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/INTERRUZIONE-6.3.jpg-2.webp\"\r\n                                                        title=\"INTERRUZIONE-6.3.jpg-2\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>Le chapitre 6 est une norme d\u00e9crivant les mesures de protection contre les chocs \u00e9lectiques.<\/p>\n","protected":false},"author":182,"featured_media":36598,"parent":36544,"menu_order":3,"template":"","meta":{"_acf_changed":false,"footnotes":""},"normative-tecniche":[165],"class_list":["post-36597","normativa_tecnica","type-normativa_tecnica","status-publish","has-post-thumbnail","hentry","tipologia_normativa-normes-iec"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"Le chapitre 6 est une norme d\u00e9crivant les mesures de protection contre les chocs \u00e9lectiques.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-07T07:43:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"200\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/\",\"name\":\"6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp\",\"datePublished\":\"2023-01-04T16:58:27+00:00\",\"dateModified\":\"2025-07-07T07:43:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp\",\"width\":200,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Normes techniques\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/normative-tecniche\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Normes IEC\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"EN 60204-1 : Equipement \u00e9lectrique des machines\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"6 &#8211; Protection contre les chocs \u00e9lectriques\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/","og_locale":"fr_FR","og_type":"article","og_title":"6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering","og_description":"Le chapitre 6 est une norme d\u00e9crivant les mesures de protection contre les chocs \u00e9lectiques.","og_url":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/","og_site_name":"Gt-Engineering","article_modified_time":"2025-07-07T07:43:35+00:00","og_image":[{"width":200,"height":200,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/","url":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/","name":"6 - Protection contre les chocs \u00e9lectriques - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp","datePublished":"2023-01-04T16:58:27+00:00","dateModified":"2025-07-07T07:43:35+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/06\/IPXXB-2-200x200-1.webp","width":200,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/6-protection-contre-les-chocs-electriques\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.gt-engineering.it\/fr\/"},{"@type":"ListItem","position":2,"name":"Normes techniques","item":"https:\/\/www.gt-engineering.it\/fr\/normative-tecniche\/"},{"@type":"ListItem","position":3,"name":"Normes IEC","item":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/"},{"@type":"ListItem","position":4,"name":"EN 60204-1 : Equipement \u00e9lectrique des machines","item":"https:\/\/www.gt-engineering.it\/fr\/reglements-techniques\/normes-iec\/iec-60204-1-equipement-electrique-des-machines\/"},{"@type":"ListItem","position":5,"name":"6 &#8211; Protection contre les chocs \u00e9lectriques"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/fr\/#website","url":"https:\/\/www.gt-engineering.it\/fr\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/36597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/types\/normativa_tecnica"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/users\/182"}],"version-history":[{"count":16,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/36597\/revisions"}],"predecessor-version":[{"id":48192,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/36597\/revisions\/48192"}],"up":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normativa_tecnica\/36544"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media\/36598"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media?parent=36597"}],"wp:term":[{"taxonomy":"tipologia_normativa","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/normative-tecniche?post=36597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}