{"id":48203,"date":"2025-06-27T14:56:03","date_gmt":"2025-06-27T13:56:03","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=approfondimento&#038;p=48203"},"modified":"2025-07-27T06:41:47","modified_gmt":"2025-07-27T05:41:47","slug":"pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique","status":"publish","type":"approfondimento","link":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/","title":{"rendered":"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-none\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    Le Doute    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale-150x150.jpeg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"169\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale-300x169.jpeg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"432\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale-768x432.jpeg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"576\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale-1024x576.jpeg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg.webp\"\r\n                                                        title=\"foto sito principale\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Qu\u2019est-ce que c&rsquo;est le pouvoir assign\u00e9 de coupure d\u2019un disjoncteur magn\u00e9to-thermique (Disjoncteur) ou d\u2019un fusible ?<\/p>\n<blockquote><p>[IEC 60947-1: 2020] <strong><em>3.4 Appareils de connexion<br \/>\n<\/em><\/strong><em><strong>3.4.11<\/strong> <strong>disjoncteur.<\/strong> Appareil m\u00e9canique de connexion capable d\u2019\u00e9tablir, de supporter et d\u2019interrompre des courants dans les conditions normales du circuit, ainsi que d\u2019\u00e9tablir, de supporter pendant <\/em><em>une dur\u00e9e sp\u00e9cifi\u00e9e et d\u2019interrompre des courants dans des conditions anormales sp\u00e9cifi\u00e9es du circuit telles que celles du court-circuit<\/em><\/p>\n<p>[IEC TR 61912-1:2007] <strong>D<\/strong><em><strong>ispositif de protection contre les courts-circuits (DPCC).<\/strong> Dispositif destin\u00e9 \u00e0 prot\u00e9ger un circuit ou des parties d&rsquo;un circuit contre les courants de court-circuit par l\u2019interruption de ceux-ci<\/em><\/p><\/blockquote>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        \n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-none\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    Consid\u00e9ration 2 : Pouvoir assign\u00e9 de coupure et normes applicables    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/immagine-sito-150x150.jpg\"\r\n                                type=\"image\/jpeg\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"225\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/immagine-sito-300x225.jpg\"\r\n                                type=\"image\/jpeg\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"576\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/immagine-sito-768x576.jpg\"\r\n                                type=\"image\/jpeg\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"768\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/immagine-sito-1024x768.jpg\"\r\n                                type=\"image\/jpeg\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/immagine-sito-scaled.jpg\"\r\n                                                        title=\"immagine sito\"\r\n                                                        type=\"image\/jpeg\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Le pouvoir assign\u00e9 de coupure, ou Icn\/Icu, du dispositif de protection est fondamental pour la protection contre les courts-circuits.<\/p>\n<p>Pouvoir assign\u00e9 de coupure : c\u2019est le courant maximal que le dispositif est capable d\u2019interrompre en toute s\u00e9curit\u00e9, sans dommage. En termes simples, c\u2019est la capacit\u00e9 d\u2019un dispositif de protection \u00e0 ouvrir un court-circuit lorsque la valeur du courant atteint celle d\u2019un court-circuit.<\/p>\n<blockquote><p><em>[IEC 60947-2: 2024] <\/em><strong><em>4.3.6.2 Pouvoirs de coupure en court-circuit assign\u00e9s <\/em><\/strong><\/p>\n<p><em><strong>4.3.6.2.1 G\u00e9n\u00e9ralit\u00e9s<\/strong> : Les pouvoirs de coupure assign\u00e9s d\u2019un disjoncteur sont les valeurs attribu\u00e9es par le fabricant pour une tension de fonctionnement assign\u00e9e, dans des conditions sp\u00e9cifi\u00e9es. <\/em><\/p>\n<p><em>Un pouvoir assign\u00e9 de coupure implique que le disjoncteur est capable d\u2019interrompre tout courant de court-circuit jusqu\u2019\u00e0 la valeur sp\u00e9cifi\u00e9e, \u00e0 une tension de r\u00e9tablissement \u00e0 fr\u00e9quence industrielle correspondant aux valeurs de test prescrites.<\/em><\/p><\/blockquote>\n<p>Il est important de noter qu\u2019un seul appareil peut avoir plusieurs valeurs de pouvoir assign\u00e9 de coupure selon la norme consid\u00e9r\u00e9e. Deux normes d\u00e9finissent ces valeurs :<\/p>\n<ul>\n<li>EN 60947-2 : pour les disjoncteurs \u00e0 usage industriel<\/li>\n<li>EN 60898-1 : pour les disjoncteurs \u00e0 usage domestique<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    EN 60947-2: 2016. Appareillage \u00e0 basse tension \u2013 Partie 2 : Disjoncteurs    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La norme IEC 60947-2 d\u00e9finit deux types de pouvoir assign\u00e9 de coupure :<\/p>\n<ul>\n<li><strong>\u00a0Icu<\/strong> (pouvoir assign\u00e9 de coupure ultime) : la valeur maximale de courant que le disjoncteur peut interrompre, test\u00e9e selon la s\u00e9quence O-t-CO.<\/li>\n<\/ul>\n<blockquote><p><em>[IEC 60947-2: 2016] 8.3.2.6.4.4 Op\u00e9rations d&rsquo;essai \u2013 Les symboles suivants sont utilis\u00e9s pour d\u00e9finir les s\u00e9quences d\u2019op\u00e9rations :<\/em><\/p>\n<p><em>O repr\u00e9sente une op\u00e9ration d\u2019ouverture.<\/em><\/p>\n<p><em>CO repr\u00e9sente une fermeture suivie, apr\u00e8s un d\u00e9lai appropri\u00e9, d\u2019une ouverture.<\/em><\/p>\n<p><em>t repr\u00e9sente l\u2019intervalle de temps entre deux op\u00e9rations de court-circuit successives, qui doit \u00eatre aussi court que possible, en respectant le temps de r\u00e9initialisation du disjoncteur (voir 2.19), mais pas inf\u00e9rieur \u00e0 3 min.<\/em><\/p>\n<p><em>Le temps de r\u00e9initialisation maximal est de 15 min (ou plus selon le fabricant), sans d\u00e9placement du disjoncteur. Toute tentative de r\u00e9enclenchement doit \u00eatre espac\u00e9e d&rsquo;au moins 1 min.<\/em><\/p>\n<p><em>La valeur maximale de I\u00b2t (voir 2.5.18 de l\u2019IEC 60947-1:2007) peut \u00eatre consign\u00e9e dans le rapport d\u2019essai (voir 7.2.1.2.4 a)).<\/em><\/p><\/blockquote>\n<p>Apr\u00e8s l\u2019essai, l\u2019appareil doit fonctionner \u00e0 son courant nominal.<\/p>\n<blockquote><p><em>[IEC 60947-2: 2016] <strong>4.3.6.2.2 Pouvoir assign\u00e9 de coupure ultime (Icu)<\/strong> : c\u2019est la valeur de courant assign\u00e9e maximale que le disjoncteur peut interrompre dans les conditions sp\u00e9cifi\u00e9es au paragraphe 8.3.5.\u00a0Exprim\u00e9e en kA (valeur efficace du courant alternatif, le cas \u00e9ch\u00e9ant). <\/em><\/p><\/blockquote>\n<ul>\n<li><strong>Ics<\/strong> (pouvoir assign\u00e9 de coupure de service) : c\u2019est la capacit\u00e9 de l\u2019appareil \u00e0 couper plusieurs courts-circuits successifs, selon la s\u00e9quence O-t-CO-t-CO, et \u00e0 rester op\u00e9rationnel \u00e0 son courant nominal.<\/li>\n<\/ul>\n<blockquote><p><em>[IEC 60947-2: 2016] 8.3.2.6.4.4 Op\u00e9rations d&rsquo;essai<\/em><br data-start=\"202\" data-end=\"205\" \/><em>Les symboles suivants sont utilis\u00e9s pour d\u00e9finir la s\u00e9quence des op\u00e9rations :<\/em><\/p>\n<ul>\n<li data-start=\"290\" data-end=\"338\"><em>O repr\u00e9sente une op\u00e9ration de coupure.<\/em><\/li>\n<li data-start=\"341\" data-end=\"456\"><em>CO repr\u00e9sente une fermeture suivie, apr\u00e8s un temps d\u2019ouverture appropri\u00e9, d\u2019une op\u00e9ration de coupure.<\/em><\/li>\n<li data-start=\"459\" data-end=\"779\"><em>t repr\u00e9sente l\u2019intervalle de temps entre deux op\u00e9rations de court-circuit successives, qui doit \u00eatre aussi court que possible, tout en tenant compte du temps de r\u00e9armement du disjoncteur (voir 2.19), sans \u00eatre inf\u00e9rieur \u00e0 3 minutes. La valeur r\u00e9elle de t doit \u00eatre indiqu\u00e9e dans le rapport d\u2019essai.<\/em><\/li>\n<\/ul>\n<p><em>Le temps de r\u00e9armement maximal doit \u00eatre de 15 minutes, ou toute autre dur\u00e9e plus longue pr\u00e9cis\u00e9e par le fabricant, sans toutefois exc\u00e9der 1 heure, pendant laquelle le disjoncteur ne doit pas \u00eatre d\u00e9plac\u00e9. Toute tentative de r\u00e9enclenchement pendant cette p\u00e9riode doit \u00eatre espac\u00e9e d\u2019au moins 1 minute.<\/em><\/p>\n<p><em>La valeur maximale de I\u00b2t (voir 2.5.18 de l\u2019IEC 60947-1:2007) pendant ces essais peut \u00eatre consign\u00e9e dans le rapport d\u2019essai (voir 7.2.1.2.4, point a)).<\/em><\/p>\n<p data-start=\"138\" data-end=\"530\"><em>[IEC 60947-2: 2016] <strong>4.3.6.2.3 Pouvoir assign\u00e9 de coupure en service en court-circuit (Ics)<\/strong><\/em><br data-start=\"224\" data-end=\"227\" \/><em>Le pouvoir assign\u00e9 de coupure en service en court-circuit d\u2019un disjoncteur est la valeur du pouvoir assign\u00e9 de coupure en service (voir 2.15.2) attribu\u00e9e \u00e0 ce disjoncteur par le fabricant, pour la tension de fonctionnement assign\u00e9e correspondante, dans les conditions sp\u00e9cifi\u00e9es au paragraphe 8.3.4.<\/em><\/p>\n<p data-start=\"532\" data-end=\"682\"><em>Il est exprim\u00e9 soit comme une valeur du courant de coupure pr\u00e9sum\u00e9, en kA, soit comme un pourcentage de Icu (par exemple : Ics = 25 % de Icu).<\/em><\/p>\n<p data-start=\"684\" data-end=\"744\"><em>La valeur de Ics doit \u00eatre au moins \u00e9gale \u00e0 25 % de Icu.<\/em><\/p>\n<\/blockquote>\n<p data-start=\"684\" data-end=\"744\">En r\u00e8gle g\u00e9n\u00e9rale, <strong data-start=\"767\" data-end=\"795\">Ics est inf\u00e9rieure \u00e0 Icn<\/strong>.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/Tabella-ICN-e-iCS-150x150.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"103\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/Tabella-ICN-e-iCS-300x103.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"264\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/Tabella-ICN-e-iCS-768x264.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 1024px)\"\r\n                                width=\"1024\"\r\n                                height=\"352\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/Tabella-ICN-e-iCS-1024x352.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/Tabella-ICN-e-iCS.jpg.webp\"\r\n                                                        title=\"Tabella ICN e iCS\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La norme <strong data-start=\"71\" data-end=\"86\">IEC 60898-1<\/strong> d\u00e9finit <strong data-start=\"95\" data-end=\"102\">Icn<\/strong> comme le <strong data-start=\"112\" data-end=\"142\">pouvoir de coupure nominal<\/strong> ou <strong data-start=\"146\" data-end=\"188\">pouvoir de court-circuit nominal (Icn)<\/strong>, c\u2019est-\u00e0-dire la valeur attribu\u00e9e \u00e0 ce disjoncteur par le fabricant, selon une <strong>s\u00e9quence d\u2019essais sp\u00e9cifique<\/strong>.<\/p>\n<blockquote><p><strong><em>[IEC 60898-1:2020] 5.2.4 Pouvoir assign\u00e9 de coupure nominal (Icn)<\/em><\/strong><\/p>\n<p><em>Le pouvoir assign\u00e9 de coupure nominal d\u2019un disjoncteur est la valeur de coupure ultime attribu\u00e9e par le fabricant.<\/em><\/p>\n<p><em>NOTE : un disjoncteur ayant un pouvoir assign\u00e9 de coupure nominal donn\u00e9 poss\u00e8de un Ics correspondant.<\/em><\/p><\/blockquote>\n<p><strong data-start=\"99\" data-end=\"108\">L\u2019Icn<\/strong>, selon la norme <strong data-start=\"125\" data-end=\"140\">IEC 60898-1<\/strong>, suit des <strong data-start=\"151\" data-end=\"176\">exigences de s\u00e9quence<\/strong> analogues \u00e0 celles de <strong data-start=\"199\" data-end=\"208\">l\u2019Icu<\/strong> selon la <strong data-start=\"218\" data-end=\"233\">IEC 60947-2<\/strong>, mais pr\u00e9sente n\u00e9anmoins certaines <strong data-start=\"269\" data-end=\"284\">diff\u00e9rences<\/strong>.<\/p>\n<blockquote>\n<p data-start=\"175\" data-end=\"535\"><em>[IEC 60898-2: 2021] 9.12.11.4.3 Essai \u00e0 la capacit\u00e9 de coupure nominale (Icn)<\/em><br data-start=\"256\" data-end=\"259\" \/><em>Remplacement du premier paragraphe :<\/em><br data-start=\"299\" data-end=\"302\" \/><em>a) Le circuit d\u2019essai est calibr\u00e9 conform\u00e9ment aux sections 9.12.7.1 et 9.12.7.2, en courant alternatif avec un facteur de puissance selon le tableau 17, ou en courant continu avec une constante de temps selon 9.12.5.<\/em><\/p>\n<p data-start=\"537\" data-end=\"836\"><em>Ajout :<\/em><br data-start=\"548\" data-end=\"551\" \/><em>c) Dans le cas du courant continu, la s\u00e9quence d\u2019essai pour les disjoncteurs unipolaires et bipolaires est :<\/em><br data-start=\"671\" data-end=\"674\" \/><em>O \u2013 t \u2013 CO<\/em><br data-start=\"688\" data-end=\"691\" \/><em>Deux op\u00e9rations sont effectu\u00e9es : le circuit est ferm\u00e9 une fois par l\u2019interrupteur auxiliaire A, et une fois par le disjoncteur lui-m\u00eame.<\/em><\/p>\n<\/blockquote>\n<p data-start=\"99\" data-end=\"265\">Il existe une <strong data-start=\"113\" data-end=\"128\">constante K<\/strong>, d\u00e9finie comme le <strong data-start=\"147\" data-end=\"175\">rapport entre Ics et Icn<\/strong>, qui varie en fonction de la valeur de <strong data-start=\"215\" data-end=\"222\">Icn<\/strong> consid\u00e9r\u00e9e, comme indiqu\u00e9 dans le tableau.<\/p>\n<p data-start=\"267\" data-end=\"481\">Il est important de noter que, m\u00eame si le <strong data-start=\"309\" data-end=\"324\">disjoncteur<\/strong> est conforme \u00e0 la norme <strong data-start=\"349\" data-end=\"363\">EN 60947-2<\/strong>, la <strong data-start=\"368\" data-end=\"385\">valeur de Icn<\/strong> selon <strong data-start=\"392\" data-end=\"406\">EN 60898-1<\/strong> est indiqu\u00e9e en \u00e9vidence, dans un <strong data-start=\"441\" data-end=\"454\">rectangle<\/strong> visible sur le dispositif.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    Exemple    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/4\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/disp.diff_-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 252px)\"\r\n                                width=\"252\"\r\n                                height=\"300\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/disp.diff_-252x300.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 412px)\"\r\n                                width=\"412\"\r\n                                height=\"490\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/disp.diff_.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 412px)\"\r\n                                width=\"412\"\r\n                                height=\"490\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/disp.diff_.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/disp.diff_.png.webp\"\r\n                                                        title=\"disp.diff\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Un exemple : le disjoncteur diff\u00e9rentiel Bticino mod\u00e8le G23AC32, dans l\u2019angle inf\u00e9rieur gauche, indique la valeur de <strong>Icn<\/strong> selon la norme <strong>IEC 60898-1.<\/strong><\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    Conclusions    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Le pouvoir assign\u00e9 de coupure d\u2019un disjoncteur est le courant maximal qu\u2019il peut interrompre.<\/p>\n<p><strong>Deux normes principales existent<\/strong> : l\u2019IEC 60898-1 (usage domestique) et l\u2019IEC 60947-2 (usage industriel).<\/p>\n<p>Les valeurs de pouvoir assign\u00e9 de coupure selon la norme industrielle sont g\u00e9n\u00e9ralement plus \u00e9lev\u00e9es.<\/p>\n<p>Un dispositif conforme \u00e0 la norme IEC 60898-1<strong> peut aussi \u00eatre utilis\u00e9 en milieu industrie<\/strong>l, mais pas l\u2019inverse.<\/p>\n<p>Pour le calcul du <strong>courant de court-circuit de l&rsquo;\u00e9quipement \u00e9lectrique (SCCR) <\/strong>dans les \u00e9quipements, le constructeur peut se baser sur la Icu selon IEC 60947-2.<\/p>\n<p><strong>Concernant les fusibles<\/strong>, un seul pouvoir assign\u00e9 de coupure est g\u00e9n\u00e9ralement d\u00e9clar\u00e9. En r\u00e8gle g\u00e9n\u00e9rale, les fusibles ont un pouvoir assign\u00e9 de coupure sup\u00e9rieur \u00e0 celui des disjoncteurs.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>L\u2019un des probl\u00e8mes li\u00e9s \u00e0 la dangerosit\u00e9 du courant \u00e9lectrique est que les c\u00e2bles et les r\u00e9cepteurs peuvent prendre feu s\u2019ils sont travers\u00e9s par un courant sup\u00e9rieur \u00e0 celui pr\u00e9vu pour leur fonctionnement normal.<\/p>\n","protected":false},"author":2,"featured_media":47771,"parent":0,"menu_order":9,"template":"","meta":{"_acf_changed":false,"footnotes":""},"tipologia_approfondimento":[158],"class_list":["post-48203","approfondimento","type-approfondimento","status-publish","has-post-thumbnail","hentry","tipologia_approfondimento-securite-electrique"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"L\u2019un des probl\u00e8mes li\u00e9s \u00e0 la dangerosit\u00e9 du courant \u00e9lectrique est que les c\u00e2bles et les r\u00e9cepteurs peuvent prendre feu s\u2019ils sont travers\u00e9s par un courant sup\u00e9rieur \u00e0 celui pr\u00e9vu pour leur fonctionnement normal.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-27T05:41:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"2364\" \/>\n\t<meta property=\"og:image:height\" content=\"1330\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/\",\"name\":\"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg\",\"datePublished\":\"2025-06-27T13:56:03+00:00\",\"dateModified\":\"2025-07-27T05:41:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg\",\"width\":2364,\"height\":1330},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00c0 \u00e9tudier\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/approfondimenti\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"S\u00e9curit\u00e9 Electrique\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/","og_locale":"fr_FR","og_type":"article","og_title":"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering","og_description":"L\u2019un des probl\u00e8mes li\u00e9s \u00e0 la dangerosit\u00e9 du courant \u00e9lectrique est que les c\u00e2bles et les r\u00e9cepteurs peuvent prendre feu s\u2019ils sont travers\u00e9s par un courant sup\u00e9rieur \u00e0 celui pr\u00e9vu pour leur fonctionnement normal.","og_url":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/","og_site_name":"Gt-Engineering","article_modified_time":"2025-07-27T05:41:47+00:00","og_image":[{"width":2364,"height":1330,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/","url":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/","name":"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg","datePublished":"2025-06-27T13:56:03+00:00","dateModified":"2025-07-27T05:41:47+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2025\/06\/foto-sito-principale.jpeg","width":2364,"height":1330},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/pouvoir-assigne-de-coupure-des-dispositifs-de-protection-electrique\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.gt-engineering.it\/fr\/"},{"@type":"ListItem","position":2,"name":"\u00c0 \u00e9tudier","item":"https:\/\/www.gt-engineering.it\/fr\/approfondimenti\/"},{"@type":"ListItem","position":3,"name":"S\u00e9curit\u00e9 Electrique","item":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/"},{"@type":"ListItem","position":4,"name":"Pouvoir assign\u00e9 de coupure des dispositifs de protection \u00e9lectrique"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/fr\/#website","url":"https:\/\/www.gt-engineering.it\/fr\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/48203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/types\/approfondimento"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/users\/2"}],"version-history":[{"count":10,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/48203\/revisions"}],"predecessor-version":[{"id":48716,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/48203\/revisions\/48716"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media\/47771"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media?parent=48203"}],"wp:term":[{"taxonomy":"tipologia_approfondimento","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/tipologia_approfondimento?post=48203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}