{"id":39736,"date":"2023-02-22T11:52:44","date_gmt":"2023-02-22T10:52:44","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=approfondimento&#038;p=39736"},"modified":"2023-07-21T09:27:59","modified_gmt":"2023-07-21T08:27:59","slug":"faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose","status":"publish","type":"approfondimento","link":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/","title":{"rendered":"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>IEC 60204-1 VS IEC 60445 : conducteur de terre fonctionnel vert et jaune VS conducteur de terre fonctionnel rose.<\/p>\n<p>&nbsp;<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-left text-primary font-heading text-2xl lg:text-3xl xl:text-4xl font-normal mt-2 first:mt-0\">\n                    LA QUESTION    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png-150x150.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"163\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png-300x163.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 768px)\"\r\n                                width=\"768\"\r\n                                height=\"418\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png-768x418.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 780px)\"\r\n                                width=\"780\"\r\n                                height=\"425\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\"\r\n                                                        title=\"image-2.png\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La mise \u00e0 la terre fonctionnelle n&rsquo;est pas utilis\u00e9e pour la protection contre les contacts indirects, mais pour.. :<\/p>\n<ul>\n<li>le blindage des c\u00e2bles de signaux<\/li>\n<li>le \u00ab\u00a00\u00a0\u00bb ou le \u00ab\u00a0commun\u00a0\u00bb de la partie commande et de l&rsquo;\u00e9lectronique<\/li>\n<li>tous les dispositifs devant \u00eatre mis \u00e0 la terre pour des raisons de compatibilit\u00e9 \u00e9lectromagn\u00e9tique (CEM).<\/li>\n<\/ul>\n<p>La norme IEC 60445 doit-elle donc \u00eatre appliqu\u00e9e aux machines ? Est-il n\u00e9cessaire de connecter un conducteur de terre fonctionnel rose ?<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-left text-primary font-heading text-2xl lg:text-3xl xl:text-4xl font-normal mt-2 first:mt-0\">\n                    CONSIDERATIONS    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Immaginearticolo.png-150x150.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"214\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Immaginearticolo.png-300x214.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 613px)\"\r\n                                width=\"613\"\r\n                                height=\"438\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Immaginearticolo.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 613px)\"\r\n                                width=\"613\"\r\n                                height=\"438\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Immaginearticolo.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Immaginearticolo.png.webp\"\r\n                                                        title=\"Immaginearticolo.png\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>La r\u00e9ponse \u00e0 cette question se trouve au d\u00e9but de la IEC 60445, \u00e0 la section 1 \u00ab\u00a0Champ d&rsquo;application\u00a0\u00bb :<\/p>\n<blockquote><p>Cette publication de base sur la s\u00e9curit\u00e9 est principalement destin\u00e9e \u00e0 \u00eatre utilis\u00e9e par les comit\u00e9s d&rsquo;\u00e9tudes pour la pr\u00e9paration des normes conform\u00e9ment aux principes \u00e9tablis dans le Guide 104 de la CEI et le Guide 51 de l&rsquo;ISO\/IEC.<br \/>\nElle n&rsquo;est pas destin\u00e9e \u00e0 \u00eatre utilis\u00e9e par les fabricants ou les organismes de certification. L&rsquo;une des responsabilit\u00e9s d&rsquo;un comit\u00e9 d&rsquo;\u00e9tudes est, le cas \u00e9ch\u00e9ant, d&rsquo;utiliser les publications fondamentales de s\u00e9curit\u00e9 dans la pr\u00e9paration de ses publications. Les exigences de la pr\u00e9sente publication de base sur la s\u00e9curit\u00e9 ne s&rsquo;appliqueront pas \u00e0 moins qu&rsquo;il n&rsquo;y soit sp\u00e9cifiquement fait r\u00e9f\u00e9rence ou qu&rsquo;elles ne soient incluses dans les publications pertinentes.<\/p><\/blockquote>\n<p>Il est explicitement indiqu\u00e9 que la pr\u00e9sente norme est une norme fondamentale de s\u00e9curit\u00e9 de cat\u00e9gorie A et qu&rsquo;elle s&rsquo;adresse aux membres du comit\u00e9 technique qui l&rsquo;ont r\u00e9dig\u00e9e et non \u00e0 un utilisateur final ou \u00e0 un fabricant. Si l&rsquo;on suit ce qui est \u00e9crit, il n&rsquo;y a aucune raison d&rsquo;appliquer la norme IEC 60445 et d&rsquo;installer ensuite un c\u00e2ble de mise \u00e0 la terre fonctionnel rose \u00e0 l&rsquo;int\u00e9rieur d&rsquo;un panneau de commande industriel.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-left text-primary font-heading text-2xl lg:text-3xl xl:text-4xl font-normal mt-2 first:mt-0\">\n                    QUELLE EST LA NORME \u00c0 APPLIQUER ? ROSE OU VERT ET JAUNE ?    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Articolocavorosa1.png-150x150.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"204\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Articolocavorosa1.png-300x204.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 746px)\"\r\n                                width=\"746\"\r\n                                height=\"507\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Articolocavorosa1.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 746px)\"\r\n                                width=\"746\"\r\n                                height=\"507\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Articolocavorosa1.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/Articolocavorosa1.png.webp\"\r\n                                                        title=\"Articolocavorosa1.png\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Les normes de \u00ab\u00a0cat\u00e9gorie B\u00a0\u00bb, normes de s\u00e9curit\u00e9 de groupe, s&rsquo;adressent \u00e0 la fois aux r\u00e9dacteurs de normes de produits et aux fabricants ou laboratoires d&rsquo;essais.<\/p>\n<p>Les normes de \u00ab\u00a0cat\u00e9gorie C\u00a0\u00bb, normes de s\u00e9curit\u00e9 des produits, s&rsquo;adressent aux fabricants ; par exemple, la IEC 60204-1 s&rsquo;adresse aux fabricants de panneaux de commande industriels.<\/p>\n<p>\u00c0 ce stade, un fabricant sait qu&rsquo;il doit se r\u00e9f\u00e9rer \u00e0 la norme de cat\u00e9gorie C IEC 60204-1 et non \u00e0 la norme de cat\u00e9gorie A IEC 60445. En outre, la norme IEC 60204-1 ne pr\u00e9cise pas la couleur des conducteurs de mise \u00e0 la terre fonctionnelle. Par cons\u00e9quent, le conducteur fonctionnel de mise \u00e0 la terre peut \u00eatre <strong>vert et jaune<\/strong> (choix raisonnable pour des raisons de commodit\u00e9 et d&rsquo;habitude) ou de toute autre couleur, mais pas n\u00e9cessairement rose.<\/p>\n<p>Un autre d\u00e9bat similaire concerne les couleurs des conducteurs triphas\u00e9s \u00e0 l&rsquo;int\u00e9rieur d&rsquo;un panneau de contr\u00f4le industriel. La norme IEC 60445 recommande les couleurs des trois phases (leurs conducteurs sont indiqu\u00e9s comme Ligne 1, Ligne 2 et Ligne 3 et les bornes comme U, V et W) : elles sont respectivement noire, brune et grise. Or, dans la norme IEC 60204-1, il est \u00e9crit :<\/p>\n<blockquote><p>Lorsqu&rsquo;un code couleur est utilis\u00e9 pour l&rsquo;identification des conducteurs, il est recommand\u00e9 de les coder comme suit :<\/p>\n<p>&#8211; NOIR : circuits d&rsquo;alimentation en courant alternatif et en courant continu.<\/p><\/blockquote>\n<p>Par cons\u00e9quent, si l&rsquo;on se r\u00e9f\u00e8re \u00e0 la norme IEC 60204-1, et non \u00e0 la norme IEC 60445, le<strong> NOIR<\/strong> doit \u00eatre utilis\u00e9 comme couleur des conducteurs des trois phases \u00e0 l&rsquo;int\u00e9rieur d&rsquo;un panneau de contr\u00f4le industriel.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>IEC 60204-1 VS IEC 60445 : conducteur de terre fonctionnel vert et jaune VS conducteur de terre fonctionnel rose.<\/p>\n","protected":false},"author":182,"featured_media":39737,"parent":0,"menu_order":93,"template":"","meta":{"_acf_changed":false,"footnotes":""},"tipologia_approfondimento":[158],"class_list":["post-39736","approfondimento","type-approfondimento","status-publish","has-post-thumbnail","hentry","tipologia_approfondimento-securite-electrique"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"IEC 60204-1 VS IEC 60445 : conducteur de terre fonctionnel vert et jaune VS conducteur de terre fonctionnel rose.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-21T08:27:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"780\" \/>\n\t<meta property=\"og:image:height\" content=\"425\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/\",\"name\":\"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\",\"datePublished\":\"2023-02-22T10:52:44+00:00\",\"dateModified\":\"2023-07-21T08:27:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp\",\"width\":780,\"height\":425},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00c0 \u00e9tudier\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/approfondimenti\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"S\u00e9curit\u00e9 Electrique\",\"item\":\"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/fr\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/fr\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/","og_locale":"fr_FR","og_type":"article","og_title":"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering","og_description":"IEC 60204-1 VS IEC 60445 : conducteur de terre fonctionnel vert et jaune VS conducteur de terre fonctionnel rose.","og_url":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/","og_site_name":"Gt-Engineering","article_modified_time":"2023-07-21T08:27:59+00:00","og_image":[{"width":780,"height":425,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/","url":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/","name":"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp","datePublished":"2023-02-22T10:52:44+00:00","dateModified":"2023-07-21T08:27:59+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/07\/image-2.png.webp","width":780,"height":425},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/faut-il-appliquer-une-norme-de-securite-de-base-aux-machines-le-cas-du-cable-de-mise-a-la-terre-fonctionnel-rose\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.gt-engineering.it\/fr\/"},{"@type":"ListItem","position":2,"name":"\u00c0 \u00e9tudier","item":"https:\/\/www.gt-engineering.it\/fr\/approfondimenti\/"},{"@type":"ListItem","position":3,"name":"S\u00e9curit\u00e9 Electrique","item":"https:\/\/www.gt-engineering.it\/fr\/approfondissement\/securite-electrique\/"},{"@type":"ListItem","position":4,"name":"Faut-il appliquer une norme de s\u00e9curit\u00e9 de base aux machines ? Le cas du c\u00e2ble de mise \u00e0 la terre fonctionnel rose"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/fr\/#website","url":"https:\/\/www.gt-engineering.it\/fr\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/39736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/types\/approfondimento"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/users\/182"}],"version-history":[{"count":2,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/39736\/revisions"}],"predecessor-version":[{"id":39747,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/approfondimento\/39736\/revisions\/39747"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media\/39737"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/media?parent=39736"}],"wp:term":[{"taxonomy":"tipologia_approfondimento","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/fr\/wp-json\/wp\/v2\/tipologia_approfondimento?post=39736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}