{"id":4285,"date":"2023-01-05T14:24:04","date_gmt":"2023-01-05T13:24:04","guid":{"rendered":"https:\/\/www.gt-engineering.it\/normative-tecniche\/%tipologia_normativa%\/4-7-1-1-the-ventilation\/"},"modified":"2023-07-13T11:17:15","modified_gmt":"2023-07-13T10:17:15","slug":"4-7-1-1-the-ventilation","status":"publish","type":"normativa_tecnica","link":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/","title":{"rendered":"4.7.1.1 &#8211; The Ventilation"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system-150x150.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 279px)\"\r\n                                width=\"279\"\r\n                                height=\"300\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system-279x300.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 348px)\"\r\n                                width=\"348\"\r\n                                height=\"374\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 348px)\"\r\n                                width=\"348\"\r\n                                height=\"374\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg.webp\"\r\n                                                        title=\"Ventilation system\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"margin:0cm; margin-bottom:.0001pt; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\">The ventilation is a fundamental aspect for the <strong>ATEX Standard<\/strong> because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&nbsp;of release and the ventilation.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin:0cm; margin-bottom:.0001pt; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\">In the paragraph&nbsp;<strong style=\"box-sizing:border-box; backface-visibility:hidden\"><span style=\"font-family:&quot;Calibri&quot;,sans-serif\">4.7.1.1<\/span><\/strong>&nbsp;of the standard the requested characteristic of the <strong>ventilation system<\/strong> are listed as following:<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<blockquote>\n<p style=\"margin:0cm; margin-bottom:.0001pt; text-align:justify; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\"><i><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\"><span style=\"box-sizing:border-box\"><span style=\"backface-visibility:hidden\">&quot;Spray booths shall be designed to prevent escape of air containing vapours, aerosols or coating powder to avoid generation of an atmosphere with hazardous concentrations of materials in the workshop.<\/span><\/span><\/span><\/span><\/i><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin:0cm; margin-bottom:.0001pt; text-align:justify; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><i><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\">Exhaust air from spray booths for liquid coating material shall be discharged to atmosphere.<\/span><\/span><\/i><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin:0cm; margin-bottom:.0001pt; text-align:justify; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><i><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\">External air intake and exhaust ducts shall be designed and positioned to avoid recirculation of polluted air. The dominant wind direction at the site of installation shall be taken into account.<\/span><\/span><\/i><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin:0cm; margin-bottom:.0001pt; text-align:justify; margin-right:0cm; margin-left:0cm\"><span style=\"font-size:12pt\"><span style=\"background:white\"><span style=\"line-height:18.75pt\"><span style=\"font-family:&quot;Times New Roman&quot;,serif\"><i><span lang=\"EN-GB\" style=\"font-family:&quot;Calibri&quot;,sans-serif\"><span style=\"color:#1a1a1a\">The filter media of the powder recovery system shall ensure that the residual powder concentration in air recirculated into the building is below 10 % of exposure limits.&quot;<\/span><\/span><\/i><\/span><\/span><\/span><\/span><\/p>\n<\/blockquote>\n<p style=\"margin:0cm; margin-bottom:.0001pt; text-align:justify; margin-right:0cm; margin-left:0cm\">&nbsp;<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&#038;&#8230;<\/p>\n","protected":false},"author":1,"featured_media":38948,"parent":4276,"menu_order":1,"template":"","meta":{"_acf_changed":false,"footnotes":""},"normative-tecniche":[60],"class_list":["post-4285","normativa_tecnica","type-normativa_tecnica","status-publish","has-post-thumbnail","hentry","tipologia_normativa-atex-standards"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>4.7.1.1 - The Ventilation<\/title>\n<meta name=\"description\" content=\"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&amp;...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"4.7.1.1 - The Ventilation\" \/>\n<meta property=\"og:description\" content=\"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&amp;...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-13T10:17:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"348\" \/>\n\t<meta property=\"og:image:height\" content=\"374\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"4.7.1.1 - The Ventilation\" \/>\n<meta name=\"twitter:description\" content=\"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&amp;...\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/\",\"name\":\"4.7.1.1 - The Ventilation\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg\",\"datePublished\":\"2023-01-05T13:24:04+00:00\",\"dateModified\":\"2023-07-13T10:17:15+00:00\",\"description\":\"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&...\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg\",\"width\":348,\"height\":374},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Technical standards\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/normative-tecniche\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ATEX Standards\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"EN 16985: Spray booths for organic coating material \u2013 Safety Requirements\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"4.7.1.1 &#8211; The Ventilation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"4.7.1.1 - The Ventilation","description":"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/","og_locale":"en_US","og_type":"article","og_title":"4.7.1.1 - The Ventilation","og_description":"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&...","og_url":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/","og_site_name":"Gt-Engineering","article_modified_time":"2023-07-13T10:17:15+00:00","og_image":[{"width":348,"height":374,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_title":"4.7.1.1 - The Ventilation","twitter_description":"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&...","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/","url":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/","name":"4.7.1.1 - The Ventilation","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg","datePublished":"2023-01-05T13:24:04+00:00","dateModified":"2023-07-13T10:17:15+00:00","description":"The ventilation is a fundamental aspect for the ATEX Standard because the likelihood of the presence of an explosive gas atmosphere depends mainly on the grade&...","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Ventilation-system.jpg","width":348,"height":374},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/4-7-1-1-the-ventilation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gt-engineering.it\/en\/"},{"@type":"ListItem","position":2,"name":"Technical standards","item":"https:\/\/www.gt-engineering.it\/en\/normative-tecniche\/"},{"@type":"ListItem","position":3,"name":"ATEX Standards","item":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/"},{"@type":"ListItem","position":4,"name":"EN 16985: Spray booths for organic coating material \u2013 Safety Requirements","item":"https:\/\/www.gt-engineering.it\/en\/technical-standards\/atex-standards\/en-16985\/"},{"@type":"ListItem","position":5,"name":"4.7.1.1 &#8211; The Ventilation"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/en\/#website","url":"https:\/\/www.gt-engineering.it\/en\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normativa_tecnica\/4285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normativa_tecnica"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/types\/normativa_tecnica"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":4,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normativa_tecnica\/4285\/revisions"}],"predecessor-version":[{"id":38952,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normativa_tecnica\/4285\/revisions\/38952"}],"up":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normativa_tecnica\/4276"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media\/38948"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media?parent=4285"}],"wp:term":[{"taxonomy":"tipologia_normativa","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/normative-tecniche?post=4285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}