{"id":41925,"date":"2023-08-10T16:32:14","date_gmt":"2023-08-10T15:32:14","guid":{"rendered":"https:\/\/www.gt-engineering.it\/?post_type=approfondimento&#038;p=41925"},"modified":"2023-08-22T08:47:50","modified_gmt":"2023-08-22T07:47:50","slug":"electromechanical-elementary-relays","status":"publish","type":"approfondimento","link":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/","title":{"rendered":"Electromechanical elementary relays"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:flex-row\">\n\n    \n\n                    <div \n                class=\"order-1 relative w-full md:w-3\/4\"\n            >\n                <div\n                    class=\"pt-6 space-y-6 w-full md:pt-0 md:space-y-4 lg:space-y-8 xl:space-y-9 md:pr-12 xl:pr-24\"\n                >\n                    \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>They are of two types:<\/p>\n<ul>\n<li><strong>Type A:<\/strong> relay in which all contacts are mechanically linked (or Forcibly guided).<\/li>\n<li><strong>Type B:<\/strong> relay containing contacts that are mechanically linked to each other as well as contacts that are not mechanically linked.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>They also have two parts only:<\/p>\n<ul>\n<li><strong>The control part:<\/strong> it is the coil that moves the auxiliary contacts. The terminals are indicated as \u201cA1\u201d and \u201cA2\u201d.<\/li>\n<li><strong>The Auxiliary contacts:<\/strong> some are normally open and some are normally closed.<\/li>\n<\/ul>\n<\/div>                <\/div>\n            <\/div>\n        \n                    <div\n                class=\"h-auto order-2 mb-8 md:mb-0   overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-9-5-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"110\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-9-5-300x110.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 625px)\"\r\n                                width=\"625\"\r\n                                height=\"230\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-9-5.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 625px)\"\r\n                                width=\"625\"\r\n                                height=\"230\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-9-5.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full mx-auto\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-9-5.png.webp\"\r\n                                                        title=\"Capture 9\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:flex-row\">\n\n    \n\n                    <div \n                class=\"order-1 relative w-full md:w-3\/4\"\n            >\n                <div\n                    class=\"pt-6 space-y-6 w-full md:pt-0 md:space-y-4 lg:space-y-8 xl:space-y-9 md:pr-12 xl:pr-24\"\n                >\n                    \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Type A relays with <strong>forcibly guided<\/strong> (mechanically linked) contacts are marked either with the words \u201ctype A\u201d or with the symbol shown in the Figure below.<\/p>\n<\/div>                <\/div>\n            <\/div>\n        \n                    <div\n                class=\"h-auto order-2 mb-8 md:mb-0   overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-10-5-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"181\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-10-5-300x181.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 304px)\"\r\n                                width=\"304\"\r\n                                height=\"183\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-10-5.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 304px)\"\r\n                                width=\"304\"\r\n                                height=\"183\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-10-5.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full mx-auto\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-10-5.png.webp\"\r\n                                                        title=\"Capture 10\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:flex-row\">\n\n    \n\n                    <div \n                class=\"order-1 relative w-full md:w-3\/4\"\n            >\n                <div\n                    class=\"pt-6 space-y-6 w-full md:pt-0 md:space-y-4 lg:space-y-8 xl:space-y-9 md:pr-12 xl:pr-24\"\n                >\n                    \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>Type B relays with forcibly guided (mechanically linked) contacts are marked either with the words \u201ctype B\u201d or with the symbols given in the Figure 4.34 {4.12.2.3.4} below.<\/p>\n<\/div>                <\/div>\n            <\/div>\n        \n                    <div\n                class=\"h-auto order-2 mb-8 md:mb-0   overflow-hidden shadow-content-image w-full md:w-1\/2\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"144\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-11-3-150x144.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 282px)\"\r\n                                width=\"282\"\r\n                                height=\"144\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-11-3.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 282px)\"\r\n                                width=\"282\"\r\n                                height=\"144\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-11-3.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 282px)\"\r\n                                width=\"282\"\r\n                                height=\"144\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-11-3.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full mx-auto\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-11-3.png.webp\"\r\n                                                        title=\"Capture 11\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>They are of two types<\/p>\n","protected":false},"author":182,"featured_media":41935,"parent":41895,"menu_order":2,"template":"","meta":{"_acf_changed":false,"footnotes":""},"tipologia_approfondimento":[51],"class_list":["post-41925","approfondimento","type-approfondimento","status-publish","has-post-thumbnail","hentry","tipologia_approfondimento-electrical-hazard-and-arc-flash-mitigation"],"acf":{"sottotitolo":"","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Electromechanical elementary relays - Gt-Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electromechanical elementary relays - Gt-Engineering\" \/>\n<meta property=\"og:description\" content=\"They are of two types\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-22T07:47:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png\" \/>\n\t<meta property=\"og:image:width\" content=\"187\" \/>\n\t<meta property=\"og:image:height\" content=\"146\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/\",\"name\":\"Electromechanical elementary relays - Gt-Engineering\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png\",\"datePublished\":\"2023-08-10T15:32:14+00:00\",\"dateModified\":\"2023-08-22T07:47:50+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png\",\"width\":187,\"height\":146},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Insights\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/approfondimenti\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Electrical Safety and Arc Flash Mitigation\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Contactors used in Safety Applications\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Electromechanical elementary relays\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electromechanical elementary relays - Gt-Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/","og_locale":"en_US","og_type":"article","og_title":"Electromechanical elementary relays - Gt-Engineering","og_description":"They are of two types","og_url":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/","og_site_name":"Gt-Engineering","article_modified_time":"2023-08-22T07:47:50+00:00","og_image":[{"width":187,"height":146,"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/","url":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/","name":"Electromechanical elementary relays - Gt-Engineering","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png","datePublished":"2023-08-10T15:32:14+00:00","dateModified":"2023-08-22T07:47:50+00:00","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/08\/Capture-8-6.png","width":187,"height":146},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/electromechanical-elementary-relays\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gt-engineering.it\/en\/"},{"@type":"ListItem","position":2,"name":"Insights","item":"https:\/\/www.gt-engineering.it\/en\/approfondimenti\/"},{"@type":"ListItem","position":3,"name":"Electrical Safety and Arc Flash Mitigation","item":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/"},{"@type":"ListItem","position":4,"name":"Contactors used in Safety Applications","item":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/contactors-used-in-safety-applications\/"},{"@type":"ListItem","position":5,"name":"Electromechanical elementary relays"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/en\/#website","url":"https:\/\/www.gt-engineering.it\/en\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/41925","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/types\/approfondimento"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/users\/182"}],"version-history":[{"count":6,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/41925\/revisions"}],"predecessor-version":[{"id":42134,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/41925\/revisions\/42134"}],"up":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/41895"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media\/41935"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media?parent=41925"}],"wp:term":[{"taxonomy":"tipologia_approfondimento","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/tipologia_approfondimento?post=41925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}