{"id":1837,"date":"2023-02-22T11:39:38","date_gmt":"2023-02-22T10:39:38","guid":{"rendered":"https:\/\/www.gt-engineering.it\/approfondimenti\/%tipologia_approfondimento%\/en-60204-1-delegate-safety\/"},"modified":"2026-04-14T15:48:40","modified_gmt":"2026-04-14T14:48:40","slug":"en-60204-1-delegate-safety","status":"publish","type":"approfondimento","link":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/","title":{"rendered":"EN 60204-1: Is it possible to delegate safety aspects to the users?"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    The doubt    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9  float-right ml-6 md:ml-4 lg:ml-8 xl:ml-9 overflow-hidden shadow-content-image w-full md:w-1\/4\"\n            >\n                \n\n    \n        \n            \n                \n                    <picture\n                        class=\"\"\n                                            >\n                                                                                                        <source\n                                media=\"(max-width: 150px)\"\n                                width=\"150\"\n                                height=\"150\"\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/foto-copertina-11-768x576.jpg-150x150.webp\"\n                                type=\"image\/webp\"\n                            \/>\n                                                                                <source\n                                media=\"(max-width: 300px)\"\n                                width=\"300\"\n                                height=\"225\"\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/foto-copertina-11-768x576.jpg-300x225.webp\"\n                                type=\"image\/webp\"\n                            \/>\n                                                                                <source\n                                media=\"(max-width: 768px)\"\n                                width=\"768\"\n                                height=\"576\"\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/foto-copertina-11-768x576.jpg.webp\"\n                                type=\"image\/webp\"\n                            \/>\n                                                                                <source\n                                media=\"(max-width: 768px)\"\n                                width=\"768\"\n                                height=\"576\"\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/foto-copertina-11-768x576.jpg.webp\"\n                                type=\"image\/webp\"\n                            \/>\n                                                                            <img\n                            class=\"a-image transparent border-image h-auto  w-full\"\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/foto-copertina-11-768x576.jpg.webp\"\n                                                        width=\"768\"\n                            height=\"576\"\n                                                                                    title=\"foto-copertina-11-768&#215;576.jpg\"\n                                                        type=\"image\/webp\"\n                            loading=\"eager\" fetchpriority=\"high\" decoding=\"async\"                        \/>\n                    <\/picture>\n\n                \n\n                    \n    \n\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"text-align: justify;\">Can the machinery manufacturer require the user to install a Fuse or a Circuit Breaker to protect its Electrical Equipment? Can he require the user to install a Residual Current Device to protect the user from Indirect Contacts (<em>Fault Protection<\/em>)?<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-xl lg:text-2xl font-normal mt-2 first:mt-0\">\n                    Consideration    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"text-align: justify;\">\u00a0Electrical Energy has two main risks:<br \/>\n&#8211;\u00a0\u00a0 \u00a0Electric Shock<br \/>\n&#8211;\u00a0\u00a0 \u00a0Fire<\/p>\n<p style=\"text-align: justify;\">The standard requires the machinery manufacturer to deal with both with the following language:<\/p>\n<blockquote>\n<p style=\"text-align: justify;\">[<a href=\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/en-iec-standards\/en-iec-60204-1-safety-of-machinery-electrical-equipment-of-machines\/\">EN 60204-1: 2018<\/a>] <strong>6. Protection against electric shock &#8211; 6.1 General<\/strong><br \/>\nThe electrical equipment <strong>shall provide protection<\/strong> of persons against electric shock by:<br \/>\n\u2013 basic protection (see 6.2 and 6.4), and;<br \/>\n\u2013 fault protection (see 6.3 and 6.4).<\/p>\n<\/blockquote>\n<p style=\"text-align: justify;\">Basic protection is to prevent <a href=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/protection-from-direct-contacts-ipxxb-or-ip2x\/\">Direct Contacts<\/a>, while Fault protection is to prevent electric shock from Indirect Contacts. Normally, in a <a href=\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/en-iec-standards\/iec-60364-4-41\/\">TN-S system<\/a> the magnetic protection opens the fault loop; for that reason, an RCD is usually not required. However, if the manufacturer needs an RCD to open certain fault loops, he cannot delegate its installation to the user. The reason is that the standard requires \u2013 the key is &#8220;<strong>shall provide&#8221;<\/strong> \u2013 the manufacturer to do that.<\/p>\n<p style=\"text-align: justify;\">Regarding the risk of fire, the language is the following:<\/p>\n<blockquote>\n<p style=\"text-align: justify;\">[<a href=\"https:\/\/www.gt-engineering.it\/en\/technical-standards\/en-iec-standards\/en-iec-60204-1-safety-of-machinery-electrical-equipment-of-machines\/\">EN 60204-1: 2018<\/a>] <strong>7.2.3 Power circuits<\/strong><br \/>\nDevices for detection and interruption of overcurrent, selected in accordance with 7.2.10, shall be applied to each live conductor including circuits supplying control circuit transformers.<\/p>\n<\/blockquote>\n<p style=\"text-align: justify;\">If a switch-Disconnector without fuses is used as a General Disconnector, its protection, for example from overload, has to be guaranteed by the fuses or circuit breakers inside the electrical equipment. In other words, the machinery manufacturer cannot ask the user to install a protection on the feeder side of the Panel and, in that way, solve his problem.<\/p>\n<p style=\"text-align: justify;\">\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-xl lg:text-2xl font-normal mt-2 first:mt-0\">\n                    Conclusion    <\/h2>\n        <\/div>\n                <\/div>\n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"text-align: justify;\">\u00a0If you are a user and you just bought a new machinery, you may verify in the Instructions for Use if the manufacturer is requiring you to install, for example, a <a href=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/use-of-type-b-residual-current-device\/\">Residual Current Device Type B<\/a>. That is something you need to discuss with him, since <strong>he is delegating you a safety aspect that he has to take care of<\/strong>. It is like if he were asking you to install a fixed guard on his machinery: without that fixed guard he cannot sign a CE Declaration of Conformity according to the Machinery Directive.<\/p>\n<p style=\"text-align: justify;\">In essence, <strong>none of the safety aspects of the Electrical Installation of machinery can be delegated to the user<\/strong>.<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<p>THE DOUBT<\/p>\n<p>Can the machinery manufacturer require the user to install a Fuse or a Circuit Breaker to protect its Electrical Equipment? Can he require th&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1838,"parent":0,"menu_order":75,"template":"","meta":{"_acf_changed":false,"footnotes":""},"tipologia_approfondimento":[51],"class_list":["post-1837","approfondimento","type-approfondimento","status-publish","has-post-thumbnail","hentry","tipologia_approfondimento-electrical-hazard-and-arc-flash-mitigation"],"acf":{"sottotitolo":"","allegati":[{"string_block":"","file_block":""}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>EN 60204-1: Is it possible to delegate safety aspects to the users?<\/title>\n<meta name=\"description\" content=\"\u00a0 THE DOUBT Can the machinery ma...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EN 60204-1: Is it possible to delegate safety aspects to the users?\" \/>\n<meta property=\"og:description\" content=\"\u00a0 THE DOUBT Can the machinery ma...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-14T14:48:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"EN 60204-1: Is it possible to delegate safety aspects to the users?\" \/>\n<meta name=\"twitter:description\" content=\"\u00a0 THE DOUBT Can the machinery ma...\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/\",\"url\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/\",\"name\":\"EN 60204-1: Is it possible to delegate safety aspects to the users?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.gt-engineering.it\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/foto-copertina-11.jpg\",\"datePublished\":\"2023-02-22T10:39:38+00:00\",\"dateModified\":\"2026-04-14T14:48:40+00:00\",\"description\":\"\u00a0 THE DOUBT Can the machinery ma...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.gt-engineering.it\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/foto-copertina-11.jpg\",\"contentUrl\":\"https:\\\/\\\/www.gt-engineering.it\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/foto-copertina-11.jpg\",\"width\":800,\"height\":600,\"caption\":\"EN 60204-1: Is it possible to delegate safety aspects to the users?\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/en-60204-1-delegate-safety\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Insights\",\"item\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/approfondimenti\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Electrical Safety and Arc Flash Mitigation\",\"item\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/insights\\\/electrical-hazard-and-arc-flash-mitigation\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"EN 60204-1: Is it possible to delegate safety aspects to the users?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.gt-engineering.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EN 60204-1: Is it possible to delegate safety aspects to the users?","description":"\u00a0 THE DOUBT Can the machinery ma...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/","og_locale":"en_US","og_type":"article","og_title":"EN 60204-1: Is it possible to delegate safety aspects to the users?","og_description":"\u00a0 THE DOUBT Can the machinery ma...","og_url":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/","og_site_name":"Gt-Engineering","article_modified_time":"2026-04-14T14:48:40+00:00","og_image":[{"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"EN 60204-1: Is it possible to delegate safety aspects to the users?","twitter_description":"\u00a0 THE DOUBT Can the machinery ma...","twitter_image":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/","url":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/","name":"EN 60204-1: Is it possible to delegate safety aspects to the users?","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg","datePublished":"2023-02-22T10:39:38+00:00","dateModified":"2026-04-14T14:48:40+00:00","description":"\u00a0 THE DOUBT Can the machinery ma...","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/foto-copertina-11.jpg","width":800,"height":600,"caption":"EN 60204-1: Is it possible to delegate safety aspects to the users?"},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/en-60204-1-delegate-safety\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gt-engineering.it\/en\/"},{"@type":"ListItem","position":2,"name":"Insights","item":"https:\/\/www.gt-engineering.it\/en\/approfondimenti\/"},{"@type":"ListItem","position":3,"name":"Electrical Safety and Arc Flash Mitigation","item":"https:\/\/www.gt-engineering.it\/en\/insights\/electrical-hazard-and-arc-flash-mitigation\/"},{"@type":"ListItem","position":4,"name":"EN 60204-1: Is it possible to delegate safety aspects to the users?"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/en\/#website","url":"https:\/\/www.gt-engineering.it\/en\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/types\/approfondimento"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":8,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1837\/revisions"}],"predecessor-version":[{"id":51904,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1837\/revisions\/51904"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media\/1838"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media?parent=1837"}],"wp:term":[{"taxonomy":"tipologia_approfondimento","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/tipologia_approfondimento?post=1837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}