{"id":1627,"date":"2023-02-22T11:40:56","date_gmt":"2023-02-22T10:40:56","guid":{"rendered":"https:\/\/www.gt-engineering.it\/approfondimenti\/%tipologia_approfondimento%\/direttiva-atex-99-92-ce-atmosfere-esplosive\/"},"modified":"2026-03-16T09:10:28","modified_gmt":"2026-03-16T08:10:28","slug":"direttiva-atex-2014-34-ue-atmosfere-esplosive","status":"publish","type":"approfondimento","link":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/","title":{"rendered":"ATEX DIRECTIVE 99\/92\/CE AND EXPLOSION RISKS"},"content":{"rendered":"\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n        \n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"margin:0cm 0cm 8pt\"><span style=\"text-align:justify;\">Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that:<\/span><\/p>\n<blockquote>\n<p style=\"margin:0cm 0cm 8pt\"><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">In fulfilling the obligations set out in Article 17, paragraph 1, the employer shall assess the specific risks arising from explosive atmospheres, taking into account at least the following elements:<\/span><\/span><\/p>\n<p><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">(a) likelihood and duration of the presence of explosive atmospheres;<\/span><\/span><\/p>\n<p><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">(b) the likelihood that ignition sources, including electrostatic discharges, will be present and become active and effective<\/span><\/span><\/p>\n<p><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">(c) characteristics of the plant, substances used, processes and their possible interactions<\/span><\/span><\/p>\n<p><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">(d) the extent of foreseeable effects;<\/span><\/span><\/p>\n<\/blockquote>\n<p style=\"margin:0cm 0cm 8pt\"><span style=\"margin:0cm 0cm 8pt;\"><span style=\"text-align:justify;\">The purpose of Directive 99\/92\/EC is to provide <strong>the minimum requirements for improving the safety and health protection of workers potentially at risk from explosive atmospheres.<\/strong><\/span><\/span><\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-base\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h4 class=\"a-heading text-primary font-heading text-2xl lg:text-3xl xl:text-4xl font-normal mt-2 first:mt-0\">\n                    ASSESSMENT OF EXPLOSION RISK    <\/h4>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/cartello-ex-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"255\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/cartello-ex-300x255.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 339px)\"\r\n                                width=\"339\"\r\n                                height=\"288\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/cartello-ex.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 339px)\"\r\n                                width=\"339\"\r\n                                height=\"288\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/cartello-ex.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/cartello-ex.png.webp\"\r\n                                                        title=\"cartello-ex\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p style=\"margin: 0cm 0cm 8pt; text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">In order to manage the explosion hazard, a risk analysis must be carried out so that the appropriate safety measures can be taken. The steps to be taken are as follows<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Hazard identification<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Classification into zones (known as ATEX zones)<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Identification of ignition sources<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Extent of foreseeable effects<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Safety measures (prevention, protection, organisational-management measures)<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">&#8211; Risk assessment and safety measures programme<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"margin:0cm 0cm 8pt;\">The sign shown in the figure is affixed to entrances to work areas where potentially explosive atmospheres are present.<\/span><\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n\n\n\n\n    \n        <section\n            data-name=\"Contenuto testuale con immagine\"\n            class=\"bow-gte-testo-media u-spacer-2xs\"\n            id=\"\"\n        >\n            \n<div class=\"o-text-media px-side-spacer sm:px-side-spacer-sm lg:px-side-spacer-tablet 2xl:px-side-spacer-desktop flex flex-wrap items-start md:block\">\n\n    \n                    <div class=\"mb-6 relative w-full md:mb-4 lg:mb-8 xl:mb-9\">\n                \n        <div                class=\"m-headings\"\n            >\n    \n    \n<h2 class=\"a-heading text-primary font-heading text-lg lg:text-xl font-normal mt-2 first:mt-0\">\n                    Verification of compliance with ATEX Directive 2014\/34\/EU    <\/h2>\n        <\/div>\n                <\/div>\n        \n                    <div\n                class=\"h-auto mb-6 md:mb-4 lg:mb-8 xl:mb-9 float-left mr-6 md:mr-4 lg:mr-8 xl:mr-9  overflow-hidden shadow-content-image w-full md:w-1\/3\"\n            >\n                \r\n\r\n    \r\n        \r\n            \r\n                \r\n                    <picture\r\n                        class=\"\"\r\n                                            >\r\n                                                                                                        <source\r\n                                media=\"(max-width: 150px)\"\r\n                                width=\"150\"\r\n                                height=\"150\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/Senza-titolo-150x150.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 300px)\"\r\n                                width=\"300\"\r\n                                height=\"192\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/Senza-titolo-300x192.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 427px)\"\r\n                                width=\"427\"\r\n                                height=\"273\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/Senza-titolo.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                                <source\r\n                                media=\"(max-width: 427px)\"\r\n                                width=\"427\"\r\n                                height=\"273\"\r\n                                srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/Senza-titolo.png.webp\"\r\n                                type=\"image\/webp\"\r\n                            \/>\r\n                                                                            <img\r\n                            class=\"a-image transparent border-image h-auto  w-full\"\r\n                                                        srcset=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/Senza-titolo.png.webp\"\r\n                                                        title=\"Senza titolo\"\r\n                                                        type=\"image\/webp\"\r\n                        \/>\r\n                    <\/picture>\r\n\r\n                \r\n\r\n                    \r\n    \r\n            <\/div>\n        \n                    <div class=\"relative w-full\">\n                \n<div class=\"a-text font-text text-base normal mt-8 first:mt-0 space-y-4\">\n    <p>After determining the ATEX zone type of the environment on which the assessment is to be made, a verification of the suitability of the components for the 2014\/34\/EU directive must be carried out, which is why component marking is done.<\/p>\n<p><strong>Any electrical equipment<\/strong>, unless it is a <strong>Simple Apparatus<\/strong>, installed in classified area <strong>must be marked<\/strong> <strong>Ex as Equipment<\/strong> (not Component \u201cU\u201d), as expressed in the paragraph of the standard:<\/p>\n<blockquote><p><em>[IEC 60079-14: 2017] <b>\u00a0<\/b><b>4.2 Conditions of Use &#8211; 4.2.1 General<\/b><\/em><\/p>\n<p><em>With the exception of simple apparatus installed in an intrinsically safe circuit, only <b>Ex Equipment <\/b>having an Ex Equipment certificate<b>shall be used<\/b>.<\/em><\/p><\/blockquote>\n<p>&nbsp;<\/p>\n<\/div>            <\/div>\n        \n        \n                <div class=\"clear-both\"><\/div>\n        \n\n    <\/div>\n        <\/section>\n\n    \n","protected":false},"excerpt":{"rendered":"<p>Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that:<\/p>\n<p>In fulfilling the obligations set out in Article 17, paragraph 1, the empl&#8230;<\/p>\n","protected":false},"author":1,"featured_media":51744,"parent":0,"menu_order":108,"template":"","meta":{"_acf_changed":false,"footnotes":""},"tipologia_approfondimento":[53],"class_list":["post-1627","approfondimento","type-approfondimento","status-publish","has-post-thumbnail","hentry","tipologia_approfondimento-atex-risk"],"acf":{"sottotitolo":"The minimum requirements for the health and safety of workers","allegati":null},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ATEX DIRECTIVE 2014\/34\/UE AND EXPLOSION RISKS<\/title>\n<meta name=\"description\" content=\"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ATEX DIRECTIVE 99\/92\/EC AND EXPLOSION RISKS\" \/>\n<meta property=\"og:description\" content=\"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/\" \/>\n<meta property=\"og:site_name\" content=\"Gt-Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-16T08:10:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Portable-ATEX-Heaters-for-zone-1-and-zone-2-hazardous-areas-min.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ATEX DIRECTIVE 99\/92\/EC AND EXPLOSION RISKS\" \/>\n<meta name=\"twitter:description\" content=\"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Portable-ATEX-Heaters-for-zone-1-and-zone-2-hazardous-areas-min.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/\",\"name\":\"ATEX DIRECTIVE 2014\/34\/UE AND EXPLOSION RISKS\",\"isPartOf\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png\",\"datePublished\":\"2023-02-22T10:40:56+00:00\",\"dateModified\":\"2026-03-16T08:10:28+00:00\",\"description\":\"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage\",\"url\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png\",\"contentUrl\":\"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png\",\"width\":300,\"height\":209},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Insights\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/approfondimenti\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ATEX Risk\",\"item\":\"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"ATEX DIRECTIVE 99\/92\/CE AND EXPLOSION RISKS\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gt-engineering.it\/en\/#website\",\"url\":\"https:\/\/www.gt-engineering.it\/en\/\",\"name\":\"Gt-Engineering\",\"description\":\"bizonweb\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ATEX DIRECTIVE 2014\/34\/UE AND EXPLOSION RISKS","description":"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/","og_locale":"en_US","og_type":"article","og_title":"ATEX DIRECTIVE 99\/92\/EC AND EXPLOSION RISKS","og_description":"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...","og_url":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/","og_site_name":"Gt-Engineering","article_modified_time":"2026-03-16T08:10:28+00:00","og_image":[{"url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Portable-ATEX-Heaters-for-zone-1-and-zone-2-hazardous-areas-min.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"ATEX DIRECTIVE 99\/92\/EC AND EXPLOSION RISKS","twitter_description":"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...","twitter_image":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/01\/Portable-ATEX-Heaters-for-zone-1-and-zone-2-hazardous-areas-min.jpg","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/","url":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/","name":"ATEX DIRECTIVE 2014\/34\/UE AND EXPLOSION RISKS","isPartOf":{"@id":"https:\/\/www.gt-engineering.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage"},"image":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png","datePublished":"2023-02-22T10:40:56+00:00","dateModified":"2026-03-16T08:10:28+00:00","description":"Legislative Decree 81\/08 Art.290 on the assessment of explosion risks, states that: ...","breadcrumb":{"@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#primaryimage","url":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png","contentUrl":"https:\/\/www.gt-engineering.it\/wp-content\/uploads\/2023\/02\/cartello-ex-300x255-3-300x169-1.png","width":300,"height":209},{"@type":"BreadcrumbList","@id":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/direttiva-atex-2014-34-ue-atmosfere-esplosive\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gt-engineering.it\/en\/"},{"@type":"ListItem","position":2,"name":"Insights","item":"https:\/\/www.gt-engineering.it\/en\/approfondimenti\/"},{"@type":"ListItem","position":3,"name":"ATEX Risk","item":"https:\/\/www.gt-engineering.it\/en\/insights\/atex-risk\/"},{"@type":"ListItem","position":4,"name":"ATEX DIRECTIVE 99\/92\/CE AND EXPLOSION RISKS"}]},{"@type":"WebSite","@id":"https:\/\/www.gt-engineering.it\/en\/#website","url":"https:\/\/www.gt-engineering.it\/en\/","name":"Gt-Engineering","description":"bizonweb","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gt-engineering.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento"}],"about":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/types\/approfondimento"}],"author":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":10,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1627\/revisions"}],"predecessor-version":[{"id":48498,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/approfondimento\/1627\/revisions\/48498"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media\/51744"}],"wp:attachment":[{"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/media?parent=1627"}],"wp:term":[{"taxonomy":"tipologia_approfondimento","embeddable":true,"href":"https:\/\/www.gt-engineering.it\/en\/wp-json\/wp\/v2\/tipologia_approfondimento?post=1627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}